Over-fluxing

Very often, heat exchanger manufacturers increase the flux loading on components to be brazed to compensate for furnace atmosphere or other process related deficiencies. The flux is an excellent “band-aid” and can be used as such, but only while the true problems are located and rectified. Long term use of higher than recommended flux loads can lead to other problems.

Over fluxing causes more KAlF4 evaporation and condensation. This will load up the dry scrubber more quickly. White powder will accumulate more quickly on the curtains at the exit end of the furnace. If this is noticed, there is a very good chance that the dry scrubber is loading up more quickly.

There will be a more rapid build-up of the flux inside the furnace. This is a common issue with over fluxing whereby flux builds up on the muffle floor at the entrance to the cooling zone where it will solidify. This flux build up has been known to deflect the mesh belt.

There is more rapid build up of the flux on the fixtures which can significantly reduce maintenance intervals.

Over-fluxing can lead to visible flux residue on the brazed heat exchanger which may increase the incidence of flux residue fall-off. Excess flux residue dulls the appearance of a brazed heat exchanger and can also accumulate in the gasket areas causing problems with seals. Too much flux residue will also inhibit surface treatments such as painting or conversion treatments.